Chi tiết sản phẩm
Thiết bị đo áp suất CC6010-F
Thiết bị đo áp suất CC6010-F Labom Việt Nam
Labom Việt Nam
PRESSURE TRANSMITTER COMPACT – FOOD/ PHARMACEUTICAL / BIOTECH CC6010-F Labom Việt Nam
Features
- Measuring ranges 0…250 mbar up to 0…100 bar
- Linearity error including hysteresis <+ 0.2 % f.s.
- Piezoresistive measuring system
- Hygienic design according to EHEDG, FDA und GMP recommendations
- Material and surface quality according to the hygienic requirements
- Further features
Options
- Explosion protection for gases
- Classification per SIL2
- Inspection certificate material certificat as per DIN EN 10204-3.1
TECHNICAL DATA
Constructional design / case
Case design: | – fiel housing IP 65 or IP 67, with cable gland |
– right-angle plug per EN 175301-803-A (DIN 43650 Form A), IP 65 | |
– cable connection, IP 67 | |
– circular connector M12, IP 65 | |
case material stainless steel union nut: polyamide (with plug connector or cable connection for electr. connection)electronics encapsulated with silicone. | |
Inner chamber aeration for measuring ranges < 16 bar over case thread or connection cable (depending on design) | |
Process connection: | see next page or order code for variantsmaterial-Nr.: 1.4404 (316L) for the sleeves |
Temperature ranges: | ambient temperature range: -25…+70 °C storage temperature range: -10…+90 °C process temperature: see order details |
Measuring ranges/overrange limits: | see order details intermediate measuring ranges upon request |
Response time: | ≤ 20 ms |
Measuring accuracy: | see data sheet |
Auxiliary energy supply: | standard design:· – nominal voltage 24 V DC – function range 6…30 V DC – max allowable operating voltage 30 V DC |
Supply voltage influence: | ≤ 0,01 % v.E./V |
Output signal: | 4…20 mA, 2-wire technology 0…20 mA, 3-wire technology 4…20 mA, 3-wire technology 0…10 V, 3-wire technology |
Current limitation in output signal: | max. output current approx. 30 mA |
Adjusting range: | approx. ± 5 % f.s., zero point and measuring span separately adjustable |
Burden: | standard design Ra= UB-6V / 20 mA (KOhm) UB= operating voltage Ra= max. permissible burden resistance (incl. lead) |
Burden influenc: | for 500 ohm burden change: ≤ 0,1 % v.E. |
Functional safety: | EN 61508, classificatio per SIL2, TÜV-Reg.-No.44 799 13190204 |
Weights (without diaphragm seal): | – field housing: ca. 460 g – case with connector: ca. 200 g |
Installation position: | any |
EMC test: | – noise immunity according to EN 50082 section 2, version March 1995 issue for industry – emitted interference according to EN 50081 section 1, 1993 issue for residential and industrial areas |
Device emits no radiation of its own
Tests and certificates
See documents |
Type series
CC6010-F, CC6011-F, CC6020-F, CC6021-F |