- Fulfills various needs in the field of weighing, from simple level setpoint to complicated batching procedures
- Production of special software
- 24-bit A/D converter
- Fiscal memory up to 160.000 weighings -option-
- Totalisation of dosed weights according to recipe and component
- RS422/485 and RS232 serial outputs with ASCII protocols and/or Modbus RTU
- Profibus-DP, DeviceNet and Ethernet optional
- 50 different recipes can be stored and automatically printed
- Upload and download function for programming by TESTER 1006

TECHNICAL CHARACTERISTICS MC 302
| Trasducer input voltage: | 5 V (max 8 celle da 350 Ohm in parallel) |
| Measuring range: | -3.9 ÷ +3.9 mV/V |
| Input sensitivity: | 0.02 µV/ per count |
| Linearity: | <0.01% of full scale |
| Gain drift: | <0.0003% full scale/ °C |
| A/D Converter: | 24 bit |
| Internal resolution: | > 16.000.000 counts |
| Visible resolution: | 600.000 divisions displayed on net weight |
| Divisions value (adjustable): | x1, x2, x5 |
| Set decimal: | 0.0 ; 0.00 ; 0.000; 0.0000 |
| Filter: | 0.2 ÷ 50 Hz. 100 Hz during dosage |
| Tool voltage: | 230 Vac ±10% – 50/60 Hz absorbed power 7 VA (115 Vac on demand) |
| Temperature range: | -10 / +50°C |
| Storage temperature: | -20 ÷ +70°C |
| Logic output: | 6 relays (NA) MAX 115 Vac /30 Vdc 0.5 A cad. |
| Logic input: | 8 optoisolated 12 / 24 Vcc PNP |
| Serial door: | COM1: RS232 half duplex COM2: RS422/RS485 half duplex |
| Transmission distance: | 15m (RS232C), 1000m (RS422 and RS485) |
| FIELDBUS protocol: | ASCII, Modbus RTU |
| Baud rate: | 1200 ÷ 115200 adjustable |
| Regulatory compliance: | EN45501 for Metrological Norms EN50081-1 and EN50082-2 EMC EN61010-1 for Electrical Safety |
| Optional dosage software: | until 12 components with external module 8 relays with aggregation of component values and recipe. Management and inventory control Max 50 programmable recipes |
| Fiscal optional memory: | > 160.000 weighed |
| Analog optional output: | Optically isolated 16-Bit Voltage: 0÷5 or 0÷10V (R> 10 Ohm) Current: 0÷20 or 4÷20mA (R <300 Ohm); Linearity 0.03% of full scale; Temperature drift 0.001% of full scale /°C |
| Optional fieldbus avaiable: | Profibus DP, DeviceNet and ETHERNET TCP-IP external mounting on DIN guide |
| Power supply: | 12 to 24 VDC -10% to +15%, 15 VA |
Accessories are not to be considered included in the price of each product.
All the above is purely illustrative and not to be understood demanding towards Pavone Sistemi
All the above is purely illustrative and not to be understood demanding towards Pavone Sistemi




Đánh giá