- Continuous monitoring of oil mist concentration using scattered light principle
- Fully complying with the latest IMO code of practice for atmospheric oil mist detectors
- Easy to service, high sensitivity, stability and accuracy
- Easy to install, flexible system configuration
- Easy calibration check with checking rod
- A special sample flow concept entirely eliminates the danger of flow cell contamination
- Operation via local control unit or central multi-channel control unit
- Up to 40 measuring points possible
- Dual-beam method
- Option: Installation in stainless steel cabinet 1.4301 IP 55 with 2 doors and 1 window
The VisGuard measures the scattered light intensity of a sample drawn into the instrument. Filtered purge air is fed through the flow cell, thus enveloping the sample in a protective shroud of clean air. This effectively keeps the optics clean. Oil dust in the sample can be detected early to help preventing from further incidents.
Nominal range | 0 .. 100 PLA (Polystyrol-Latex-Aerosols) |
Sampletaking | Extractive |
Scale ranges | 0..0.1 / 0..0.3 / 0..1 / 0..3 / 0..10 / 0..30 / 0..100 PLA |
Protection | IP65 |
Sample temperature | -20 .. +50 °C |
Sample pressure | max. ±3’000 Pa (±30 mbar) |
Interfaces | RS232, Modbus, Profibus DP |
Ambient environment | Temperature range -20 .. +50°C |
Maximum service altitude | 3,000 m above sea level |
Power supply | 85 .. 264 V / 47 .. 440 Hz |
Number of sampling points | 1 .. 40 |